Designed and manufactured in the UK the Ethos stainless steel “twin burner” boilers have been developed to meet the requirements of today’s commercial buildings. With an unsurpassed premix burner modulation of 20 > 1 and output capability from 17.5kW >  3.3mW, the Ethos FS range ensures your building load is accurately matched whatever the season. As with the wall mounted boilers the FS range also have onboard boiler cascade control.           

 

Features

Benefits

Available in 350 and 550kW models Installation options allowing 17.5kW > 3.3mW
2 premix burners per boiler  Nox levels of 31mg/kw
Stainless  steel heat exchanger 5 year heat exchanger warranty
20 > 1  burner modulation Seasonal efficiency in excess of 95%
Onboard boiler cascade control < 75 dba

"Unsurpassed modulation of 20 > 1"

 

 

 
 
 
General
 
Model Ethos 350 Ethos 550
 
Dimensions (Height x Width x Depth) mm 1200 x 750 x 1100 1300 x 750 x 1500
Water Content of Appliance litre 25 30
Weight (Empty) kg 400 450
Flow / Return Connections BSP DN50 PN16 Flange DN65 PN16 Flange
Gas Connection BSP 1¼” 1½”
Flue Connection mm 150 180
Power Consumption W 520 910
Electrical Supply V 230 230
Frequency Hz 50 50
Fuse Protection A 10 10
Maximum Fan Speed RPM 6100 9200
Minimum Fan Speed RPM 1300 1950
 
HEATING PERFORMANCE
       
Nominal Heat Input (Nett) kW 17.5 - 350.0 27.5 - 550.0
Nominal Heat Output at 80/60°C kW 17.2 - 343.0 27.0 - 539.0
Nominal Heat Output at 50/30°C kW 18.9 - 378.0 29.7 - 594.0
G20 Maximum Gas Consumption m3/h3 34.8 53.4
G25
m3/hr 40.4 62.1
G31
mr/h3 13.6 20.9
 
TECHNICAL DATA
 
Flue Gas Dew Point °C 52 52
Flue Temperature at 80/60°C (at ambient temperature of 20°C) °C 75 75
Flue Material Temperature Class T 120 T 120
Permitted Maximum Resistance of Flue System Pa 200 250
Condensation pH Value 3.0 - 4.0 3.0 - 4.0
Maximum CH Flow Temperature °C 90 90
CH Water Pressure (Minimum / Maximum) Bar 0.5 - 6.0 0.5 - 6.0
G20 Minimum / Maximum Gas Pressure mbar 17 - 20 17 - 20
G25
mbar 17 - 20 17 - 20
G31
mbar 30 - 50 30 - 50
 
ENVIRONMENTAL DATA
 
NOX Levels mg/kW 31.0 31.0
Maximum Efficiency (Nett Non-Condensing) % 98.0 98.0
Maximum Efficiency (Nett Condensing) % 108.0 108.0
Seasonal Efficiency % 95.6 95.6

 

 

Type Ethos 350 Etho 550
mm
A
1200 1500
mm
B
420 420
mm
C
865 865
mm
D
730 730
mm
E
100 100
mm
F
400 400
mm
G
100 100
mm
H
180 180
mm
I
700 700
mm
J
1070 1070
K 2" 1 1/2"
L 1 1/4" 2 1/2"
M 1" 1"
mm
N
20 20
mm
O
150 180

 

key Connection type
1 Flow connection
2 Return Connection
3 Gas Connection
4 Flue Gas Connection
5 Condensate Connection
6 Saftey Valve Connection
 

MIKROFILL AT NEWPORT GIRLS’ HIGH SCHOOL

30/08/2016

Newport Girls’ High School in Shropshire was founded in 1920 to provide a grammar school education. The School continues to follow this ethic today with an appropriately challenging curriculum taught in a safe a. . .

MIKROFILL SUPPLY STANBROOK ABBEY HOTEL

01/01/2016

Set within the stunning grounds of a 26 acre estate, this former monastery is surrounded by the outstanding natural beauty of the Worcestershire countryside. The hotel's 56 rooms offer guests a beautiful blend of histori. . .

Icknield Community School

29/09/2015

Icknield Community School in Watlington Oxfordshire has recently replaced its aged heating plant with 2 Mikrofill Ethos FS350 floor standing condensing boilers.. . .

JUST ADD WATER Ethos floor standing condensing boiler range

20/05/2015

The floor standing range of condensing boilers offers individual outputs of 350 & 550kW and multiple outputs up to 4.4MW.. . .

GIRLS' HIGH SCHOOL MOVES UP THE EFFICIENCY TABLE

02/07/2013

Long standing mechanical contractor, Dodd Group of Telford turned to commercial boiler manufacturer Mikrofill Systems to supply cutting edge plant room equipment. . . .

MIKROFILL AT LANGLEY PARK SCHOOL

04/04/2013

Over the last couple of years, the Langley Park School for Boys underwent a major refurbishment with the secondary school being demolished and rebuilt with a new state of the art performance space.. . .

RYEDALE SWIMMING POOL

03/12/2012

Ryedale District Council decided that updating the heating & hot water systems would play a key part in improving the services to the public and reducing energy costs.. . .

MIKROSPACE - VALUE ENGINEERING

01/11/2012

Make the most efficient use of your space with Mikrofill Ethos Boilers.. . .

A MIKROFILL PREMIER, WITH PREMIER

29/11/2011

Peterborough Premier Inn Hotel has recently undergone a huge programme of development.These works went beyond the new restaurant, coffee shop and bar areas, it also included a whole new plant room which was installed by experience. . .