Key Features
  • Available in 70, 90, 110 and 130kW models - Installation options allowing 7 – 780kW
  • 10 > 1  burner modulation - Seasonal efficiency in excess of 96%
  • Stainless steel heat exchanger - 5 year heat exchanger warranty
Technical Specification
Product Code WHB300090
General
Dimensions (Height x Width x Depth) 905 mm x 530 mm x 475 mm
Appliance water content 8.8 litres
Weight - empty 91 Kg
Connections
Connections - flow / return 1¼ " BSP
Connection - gas ¾ " BSP
Connection - flue 100 mm
Connection - air supply 100 mm
Concentric (optional) 110 / 150 mm
Electrical
Power supply (Vac/Ph/Hz) 230 V a.c. / 1 / 50 Hz
Power consumption 369 W
Fuse protection 6 Amp
Fan speed - max 6700 RPM
Fan speed - min 1400 RPM
Heating Performance
Nominal heat input (nett) 9.0 - 90.0 kW
Nominal heat output at 80/60°C 8.8 - 87.5 kW
Nominal heat output at 50/30°C 9.7 - 97.2 kW
Maximum gas consumption (G20) 9.4 m3/hr
Maximum gas consumption (G25) 10.9 m3/hr
Maximum gas consumption (G31) 3.7 m3/hr
Technical Data
Flue gas dew point 52 °C
Flue temperature at 80/60°C (at ambient temperature of 20°C) 75 °C
Flue material temperature class T 120
Permitted maximum resistance of flue system* 140* Pa
* With this resistance value the heat output will remain within the specifications indicated on the dataplate; if the resistance is higher, the heat output will be reduced.
Condensation pH value 3.0 - 5.5
Maximum CH flow temperature 90 °C
CH water pressure (min - max) 0.5 - 6.0 bar
Minimum / maximum gas pressure (G20) 17 - 20 mbar
Minimum / maximum gas pressure (G25) 17 - 20 mbar
Minimum / maximum gas pressure (G31) 30 - 50 mbar
Environmental Data
Flue gas CO2 content (G20) 8.4 %
Flue gas CO2 content (G25) 8.4 %
Flue gas CO2 content (G31) 9.5 %
NOx levels 33.0 mg/kW
Maximum efficiency (nett non condensing) 97.2 %
Maximum efficiency (nett condensing) 108.0 %
Seasonal efficiency 95.46 %